Keypad Error Codes and Troubleshooting Steps

Comments

5 comments

  • Will Bradford

    How do I check wether the water inlet valve is working? I have the 05 error code. My steam unit won't produce heat above 80° and it takes it 20 mins to get to 80°

    0
  • Aliesky Cardenas

    To test the inlet valve, you must turn on the unit and see if you hear a thumping sound. If the inlet valve opens they should hear water going into the tanks. If that does not happen it’s the inlet valve. To test more in detail, please open the side panel and with a multimeter check voltage in the inlet valve. If you can see the power and the solenoid does not open, then the solenoid needs replacement.

    0
  • zjackster101

    I hear a thump but there is no water flow.
    I'm getting 7.5vdc at the water inlet valve.
    When i ground the other terminal on the inlet valve the water begins to flow.
    How do I test the water level sensors?

    0
  • zjackster101

    How do I insure the wires are connected to correct terminals?

    0
  • zjackster101

    Do I need to pull the sensor out to determine correct wire connection?

    0