  • Aliesky Cardenas commented,

    To test the inlet valve, you must turn on the unit and see if you hear a thumping sound. If the inlet valve opens they should hear water going into the tanks. If that does not happen it’s the inlet...

  • Aliesky Cardenas created an article,

    Removing Shower Panels Flow Restrictor

    Removing the flow restrictor depending on your Shower Panel Model. Please follow Instructions, A, B, or C, according to your shower panel model.      INSTRUCTION AINSTRUCTION B   INSTRUCTION C   ...

  • Aliesky Cardenas created an article,

    How To Check The Cable Connector

    This article will cover the steps to check the cable connector.   HOW TO CHECK THE CABLE CONNECTOR the cable connection must be checked by a qualified engineer according to the drawing sticker on t...

  • Aliesky Cardenas created an article,

    How To Properly Drain The Generator

      This article will cover how to properly drain a Steam Spa Generator. Auto drain: The Steam generator drains water for 5 minutes automatically 30 minutes AFTER the system is powered off. Manual dr...

  • Aliesky Cardenas created an article,

    How To Install The Control Panel And Temperature Sensor

    This article will provide all steps needed to install the control panel and temperature sensor in a Steam Spa generator. For further assistance or If you need to purchase/replace your heatin...

  • Aliesky Cardenas created an article,

    How To Properly Install Dual Steam Heads

    This article shows how to properly install a Steam Spa dual steam head system.    Always make sure there is enough space between the steam heads, as shown in the picture below.     For further assi...

  • Aliesky Cardenas created an article,

    How To Adjust The Water Pressure

    This article covers all steps required to adjust the water pressure from a Steam Spa generator.    For further assistance or If you need to purchase/replace your heating elements, please contact us...

  • Aliesky Cardenas created an article,

    Keypad Error Codes and Troubleshooting Steps

     Please find all error codes and troubleshooting steps for a Steam Spa Keypad.    ERROR CODE FAULT DESCRIPTION TROUBLESHOOTING 02 Steam generator and control panel communication failure 1) Ca...

  • Aliesky Cardenas created an article,

    How To Test Heating Elements (verify functionality)

    This article covers all steps and tools required to test your Heating Elements. This is done to verify that the heating elements function or if they need replacement.  CLICK HERE to follow instruct...

  • Aliesky Cardenas created an article,

    How To Replace Heating Elements

    This article covers all steps and tools required to change a Steam Spa generator Heating Element.     For further assistance or If you need to purchase/replace your heating elements, please conta...